跳转至内容
Merck
CN
  • Applying 'Sequential Windowed Acquisition of All Theoretical Fragment Ion Mass Spectra' (SWATH) for systematic toxicological analysis with liquid chromatography-high-resolution tandem mass spectrometry.

Applying 'Sequential Windowed Acquisition of All Theoretical Fragment Ion Mass Spectra' (SWATH) for systematic toxicological analysis with liquid chromatography-high-resolution tandem mass spectrometry.

Analytical and bioanalytical chemistry (2014-11-05)
Kathrin Arnhard, Anna Gottschall, Florian Pitterl, Herbert Oberacher
摘要

Liquid chromatography-tandem mass spectrometry (LC-MS/MS) has become an indispensable analytical technique in clinical and forensic toxicology for detection and identification of potentially toxic or harmful compounds. Particularly, non-target LC-MS/MS assays enable extensive and universal screening requested in systematic toxicological analysis. An integral part of the identification process is the generation of information-rich product ion spectra which can be searched against libraries of reference mass spectra. Usually, 'data-dependent acquisition' (DDA) strategies are applied for automated data acquisition. In this study, the 'data-independent acquisition' (DIA) method 'Sequential Windowed Acquisition of All Theoretical Fragment Ion Mass Spectra' (SWATH) was combined with LC-MS/MS on a quadrupole-quadrupole-time-of-flight (QqTOF) instrument for acquiring informative high-resolution tandem mass spectra. SWATH performs data-independent fragmentation of all precursor ions entering the mass spectrometer in 21m/z isolation windows. The whole m/z range of interest is covered by continuous stepping of the isolation window. This allows numerous repeat analyses of each window during the elution of a single chromatographic peak and results in a complete fragment ion map of the sample. Compounds and samples typically encountered in forensic casework were used to assess performance characteristics of LC-MS/MS with SWATH. Our experiments clearly revealed that SWATH is a sensitive and specific identification technique. SWATH is capable of identifying more compounds at lower concentration levels than DDA does. The dynamic range of SWATH was estimated to be three orders of magnitude. Furthermore, the >600,000 SWATH spectra matched led to only 408 incorrect calls (false positive rate = 0.06 %). Deconvolution of generated ion maps was found to be essential for unravelling the full identification power of LC-MS/MS with SWATH. With the available software, however, only semi-automated deconvolution was enabled, which rendered data interpretation a laborious and time-consuming process.

材料
产品编号
品牌
产品描述

Sigma-Aldrich
乙腈, suitable for HPLC, gradient grade, ≥99.9%
Sigma-Aldrich
2-丙醇, suitable for HPLC, 99.9%
Sigma-Aldrich
2-丙醇, ACS reagent, ≥99.5%
Sigma-Aldrich
乙腈, ACS reagent, ≥99.5%
Sigma-Aldrich
2-丙醇, BioReagent, ≥99.5%, Molecular Biology
Sigma-Aldrich
甲酸, ACS reagent, ≥96%
Sigma-Aldrich
乙腈, anhydrous, 99.8%
Sigma-Aldrich
异丙醇, meets USP testing specifications
Sigma-Aldrich
2-丙醇, HPLC Plus, for HPLC, GC, and residue analysis, 99.9%
Sigma-Aldrich
2-丙醇, anhydrous, 99.5%
Sigma-Aldrich
乙腈, suitable for HPLC, gradient grade, ≥99.9%
Sigma-Aldrich
乙腈, ≥99.9% (GC)
Sigma-Aldrich
2-丙醇, puriss. p.a., ACS reagent, reag. ISO, reag. Ph. Eur., ≥99.8% (GC)
Sigma-Aldrich
2-丙醇, Laboratory Reagent, ≥99.5%
Sigma-Aldrich
异丙醇, ≥99.7%, FCC, FG
Sigma-Aldrich
2-丙醇, puriss. p.a., ACS reagent, ≥99.8% (GC)
Sigma-Aldrich
乙腈, suitable for HPLC-GC, ≥99.8% (GC)
Sigma-Aldrich
2-丙醇, BioUltra, Molecular Biology, ≥99.5% (GC)
Sigma-Aldrich
4,4′-二氨基二苯甲烷, ≥97.0% (GC)
Supelco
2-丙醇, Pharmaceutical Secondary Standard; Certified Reference Material
Sigma-Aldrich
2-丙醇, electronic grade, 99.999% trace metals basis
Sigma-Aldrich
乙腈, biotech. grade, ≥99.93%
Sigma-Aldrich
乙腈, electronic grade, 99.999% trace metals basis
Sigma-Aldrich
2-丙醇, puriss., meets analytical specification of Ph. Eur., BP, USP, ≥99.5% (GC)
Supelco
2-丙醇, analytical standard
Sigma-Aldrich
2-丙醇, suitable for HPLC, 99.5%
Sigma-Aldrich
甲酸, ≥95%, FCC, FG
Sigma-Aldrich
乙腈, suitable for DNA synthesis, ≥99.9% (GC)
USP
2-丙醇, United States Pharmacopeia (USP) Reference Standard
Supelco
乙腈(纯品), Pharmaceutical Secondary Standard; Certified Reference Material