跳转至内容
Merck
CN
  • Estimation of the effects of longitudinal temperature gradients caused by frictional heating on the solute retention using fully porous and superficially porous sub-2μm materials.

Estimation of the effects of longitudinal temperature gradients caused by frictional heating on the solute retention using fully porous and superficially porous sub-2μm materials.

Journal of chromatography. A (2014-07-30)
Szabolcs Fekete, Jenő Fekete, Davy Guillarme
摘要

In this study, the retention changes induced by frictional heating were evaluated for model small compounds (150-190Da) and a small protein, namely insulin (5.7kDa). For this purpose, the effect of longitudinal temperature gradient caused by frictional heating was experimentally dissociated from the combined effect of pressure and frictional heating, by working either in constant and variable inlet pressure modes. Various columns packed with core-shell and fully porous sub-2μm particles were tested. It appears that frictional heating was less pronounced on the column packed with smallest core-shell particles (1.3μm), compared to the ones packed with core-shell and fully porous particles of 1.7-1.8μm. This observation was attributed to the low permeability of this material and the fact that it can only be employed in a restricted flow rate range, thus limiting the generated heat power. In addition, the thermal conductivity of the solid silica core of superficially porous particles (1.4W/m/K) is known to be much larger than that of fully porous silica. Then, the heat dissipation is improved. However, if systems with higher pressure capability would be available and the mechanical stability of 1.3μm core-shell material was extended to e.g. 2000bar, the retention would be more severely impacted. At 2000bar, ∼4.4W heat power and +30°C increase at column outlet temperature is expected. Last but not least, when analyzing large molecules, the impact of pressure overcomes the frictional heating effects. This was demonstrated in this study with insulin (∼5.7kDa).

材料
产品编号
品牌
产品描述

Sigma-Aldrich
乙腈, suitable for HPLC, gradient grade, ≥99.9%
Sigma-Aldrich
三氟乙酸, ReagentPlus®, 99%
Sigma-Aldrich
三氟乙酸, suitable for HPLC, ≥99.0%
Sigma-Aldrich
乙腈, ACS reagent, ≥99.5%
Sigma-Aldrich
乙腈, anhydrous, 99.8%
Sigma-Aldrich
三氟乙酸, puriss. p.a., suitable for HPLC, ≥99.0% (GC)
Sigma-Aldrich
乙腈, suitable for HPLC, gradient grade, ≥99.9%
Supelco
对羟基苯甲酸甲酯, Pharmaceutical Secondary Standard; Certified Reference Material
Sigma-Aldrich
乙腈, ≥99.9% (GC)
Sigma-Aldrich
三氟乙酸, ≥99%, for protein sequencing
Sigma-Aldrich
尿嘧啶, ≥99.0%
Sigma-Aldrich
乙腈, suitable for HPLC-GC, ≥99.8% (GC)
Sigma-Aldrich
4-羟基苯甲酸甲酯, ReagentPlus®, ≥99.0%, crystalline
Sigma-Aldrich
4-羟基苯甲酸乙酯, ReagentPlus®, 99%
USP
尼泊金甲酯, United States Pharmacopeia (USP) Reference Standard
Supelco
对羟基苯甲酸乙酯, Pharmaceutical Secondary Standard; Certified Reference Material
Sigma-Aldrich
4-羟基苯甲酸丁酯, ≥99.0% (GC)
Sigma-Aldrich
乙腈, biotech. grade, ≥99.93%
Sigma-Aldrich
乙腈, electronic grade, 99.999% trace metals basis
Supelco
三氟乙酸, analytical standard
Supelco
对羟基安息香甲酯, PESTANAL®, analytical standard
Supelco
对羟基苯甲酸丁酯, Pharmaceutical Secondary Standard; Certified Reference Material
Supelco
尿嘧啶, Pharmaceutical Secondary Standard; Certified Reference Material
Sigma-Aldrich
乙腈, suitable for DNA synthesis, ≥99.9% (GC)
Sigma-Aldrich
尿嘧啶, BioReagent, suitable for cell culture
Supelco
乙腈(纯品), Pharmaceutical Secondary Standard; Certified Reference Material
Sigma-Aldrich
4-羟基苯甲酸甲酯, BioReagent, suitable for insect cell culture
Supelco
乙腈, analytical standard
Sigma-Aldrich
4-羟基苯甲酸甲酯, ≥99%, FCC
Sigma-Aldrich
乙腈, ReagentPlus®, 99%