Merck
CN
  • Environmental friendly method for urban wastewater monitoring of micropollutants defined in the Directive 2013/39/EU and Decision 2015/495/EU.

Environmental friendly method for urban wastewater monitoring of micropollutants defined in the Directive 2013/39/EU and Decision 2015/495/EU.

Journal of chromatography. A (2015-10-04)
Ana R Ribeiro, Marta Pedrosa, Nuno F F Moreira, Manuel F R Pereira, Adrián M T Silva
摘要

The fate and removal of organic micropollutants in the environment is a demanding issue evidenced by the recent European policy. This work presents an analytical method for the trace quantification of 37 micropollutants including Priority Substances (Directive 2013/39/EU), substances of the recent watch list (Decision 2015/495/EU) and contaminants of emerging concern: pesticides, multi-class pharmaceuticals and a metabolite, estrogens and one industrial compound. The analytical method was based on solid phase extraction (SPE) followed by ultra-high performance liquid chromatography with tandem mass spectrometry (UHPLC-MS/MS), using eco-friendly solvents (ethanol and ultrapure water) both in the SPE and UHPLC, according to green analytical chemistry principles. Briefly, Oasis(®) HLB cartridges were used to preconcentrate 100mL of water samples and the reconstituted extracts were analyzed with a Kinetex™ column under reversed mode, the linear ranges extended to 200ngL(-1) (R(2)>0.99) for all the analytes. The method detection limits were between 0.04 and 2.26ngL(-1) and the method quantification limits were between 0.13 and 6.85ngL(-1). The identity of the compounds was confirmed using two MS/MS transitions and its ion ratios, according to Decision 2002/657/EC. The validated method was applied to wastewater treatment plant samples, assessing the concentration of micropollutants after secondary biological and tertiary UV treatments. Lab-scale photolysis and ozonation experiments were also performed with the secondary effluents, with ozonation showing the best performance for the removal of most of the determined micropollutants.

材料
货号
品牌
产品描述

Sigma-Aldrich
纯乙醇, 200 proof, for molecular biology
Sigma-Aldrich
乙腈, anhydrous, 99.8%
Sigma-Aldrich
甲醇, ACS reagent, ≥99.8%
Sigma-Aldrich
氢氧化铵 溶液, ACS reagent, 28.0-30.0% NH3 basis
Sigma-Aldrich
纯乙醇, 200 proof, anhydrous, ≥99.5%
Sigma-Aldrich
硫酸, ACS reagent, 95.0-98.0%
Sigma-Aldrich
纯乙醇, 200 proof, ACS reagent, ≥99.5%
Sigma-Aldrich
甲醇, anhydrous, 99.8%
Sigma-Aldrich
甲酸, reagent grade, ≥95%
Sigma-Aldrich
纯乙醇, 200 proof, HPLC/spectrophotometric grade
Sigma-Aldrich
甲酸, ACS reagent, ≥96%
Sigma-Aldrich
硫酸, 99.999%
Sigma-Aldrich
乙腈, ACS reagent, ≥99.5%
Sigma-Aldrich
氢氧化铵 溶液, 28% NH3 in H2O, ≥99.99% trace metals basis
Sigma-Aldrich
纯乙醇, 200 proof, meets USP testing specifications
Sigma-Aldrich
纯乙醇, 190 proof, ACS spectrophotometric grade, 95.0%
Sigma-Aldrich
乙酸铵, reagent grade, ≥98%
Sigma-Aldrich
甲醇, puriss. p.a., ACS reagent, reag. ISO, reag. Ph. Eur., ≥99.8% (GC)
Sigma-Aldrich
乙酸铵, ACS reagent, ≥97%
Sigma-Aldrich
乙酸铵, for molecular biology, ≥98%
Sigma-Aldrich
纯乙醇, 190 proof, for molecular biology
Sigma-Aldrich
纯乙醇, 190 proof, meets USP testing specifications
Sigma-Aldrich
乙酸铵, ≥99.99% trace metals basis
Sigma-Aldrich
硫酸, puriss. p.a., for determination of Hg, ACS reagent, reag. ISO, reag. Ph. Eur., 95.0-97.0%
Sigma-Aldrich
氢氧化铵 溶液, puriss., 30-33% NH3 in H2O
Sigma-Aldrich
布洛芬, ≥98% (GC)
Sigma-Aldrich
甲醇, Laboratory Reagent, ≥99.6%
Sigma-Aldrich
乙酸铵 溶液, for molecular biology, 7.5 M
Sigma-Aldrich
甲氧苄啶, ≥98.5%
Sigma-Aldrich
氢氧化铵 溶液, puriss. p.a., reag. ISO, reag. Ph. Eur., ~25% NH3 basis