Assessment of the complementarity of temperature and flow-rate for response normalisation of aerosol-based detectors.

Journal of chromatography. A (2014-07-09)
Manish M Khandagale, Emily F Hilder, Robert A Shellie, Paul R Haddad
摘要

The solvent dependency of the detection response is a major limitation of corona-charged aerosol detection (C-CAD). The present study empirically investigates the utility of temperature and flow-rate gradients to overcome solvent gradient limitations of C-CAD. In preliminary flow-injection investigations, it is demonstrated that the response of C-CAD remains relatively unaltered with variations in flow-rate when used with water-rich eluents. Based on these findings two separation approaches were developed and their utility for C-CAD response normalisation was demonstrated using a mixture of eight analytes. In the first approach the use of a solvent gradient is replaced with a temperature gradient performed under isocratic mobile phase conditions. Detection response is further enhanced by mixing a secondary stream of pure acetonitrile with the column effluent, yielding a 3-fold increase in detection response. In the second approach, flow-rate programming is used to improve speed of isocratic-temperature gradient separation. The use of simultaneous variation in flow-rate and column temperature reduced the separation time by 30%, with relatively uniform analyte response. Lastly, an inverse-gradient solvent compensation approach was used to evaluate the response homogeneity and the applicability of the above approaches for quantitative analysis. Good peak area reproducibility (RSD%<15%) and linearity (R(2)>0.994, on a log-scale) over the sample mass range of 0.1-10 μg was achieved. The response deviation across the mixture of eight compounds at seven concentration levels was 6-13% compared to 21-39% when a conventional solvent gradient was applied and this response deviation was comparable to that obtained in the inverse gradient solvent compensation approach. Finally, applicability of these approaches for typical pharmaceutical impurity profiling was demonstrated at a concentration of 5 μg/mL (0.1% of the principal compound).

材料
产品编号
品牌
产品描述

Sigma-Aldrich
乙腈, suitable for HPLC, gradient grade, ≥99.9%
Sigma-Aldrich
甲醇, suitable for HPLC, ≥99.9%
Sigma-Aldrich
甲醇, ACS reagent, ≥99.8%
Sigma-Aldrich
氢氧化铵 溶液, ACS reagent, 28.0-30.0% NH3 basis
Sigma-Aldrich
乙酸, glacial, ACS reagent, ≥99.7%
Sigma-Aldrich
甲醇, suitable for HPLC, gradient grade, ≥99.9%
Sigma-Aldrich
乙酸, glacial, ReagentPlus®, ≥99%
Sigma-Aldrich
甲醇, HPLC Plus, ≥99.9%
Sigma-Aldrich
乙腈, ACS reagent, ≥99.5%
Sigma-Aldrich
乙酸铵, ACS reagent, ≥97%
Sigma-Aldrich
乙腈, anhydrous, 99.8%
Sigma-Aldrich
氢氧化铵 溶液, 28% NH3 in H2O, ≥99.99% trace metals basis
Sigma-Aldrich
甲醇, anhydrous, 99.8%
Sigma-Aldrich
乙酸铵, ≥99.99% trace metals basis
Supelco
乙酸铵, LiChropur, eluent additive for LC-MS
Sigma-Aldrich
乙腈, suitable for HPLC, gradient grade, ≥99.9%
Sigma-Aldrich
乙酸, glacial, ≥99.99% trace metals basis
Sigma-Aldrich
乙腈, ≥99.9% (GC)
Sigma-Aldrich
乙酸 溶液, suitable for HPLC
Sigma-Aldrich
乙酸, glacial, puriss. p.a., ACS reagent, reag. ISO, reag. Ph. Eur., ≥99.8%
Sigma-Aldrich
乙酸, glacial, puriss., meets analytical specification of Ph. Eur., BP, USP, 99.8-100.5%
Sigma-Aldrich
甲醇, Laboratory Reagent, ≥99.6%
Sigma-Aldrich
甲醇, suitable for HPLC, gradient grade, suitable as ACS-grade LC reagent, ≥99.9%
Sigma-Aldrich
甲醇, puriss. p.a., ACS reagent, reag. ISO, reag. Ph. Eur., ≥99.8% (GC)
Sigma-Aldrich
氢氧化铵 溶液, puriss., 30-33% NH3 in H2O
Sigma-Aldrich
甲醇, ACS spectrophotometric grade, ≥99.9%
Sigma-Aldrich
乙酸铵, Molecular Biology, ≥98%
Sigma-Aldrich
甲醇, ACS reagent, ≥99.8%
Sigma-Aldrich
乙腈, suitable for HPLC-GC, ≥99.8% (GC)
Sigma-Aldrich
乙酸铵 溶液, Molecular Biology, 7.5 M