Merck
CN
  • Development and validation of an on-line multidimensional SPE-LC-MS/MS method for the quantitation of Tetrandrine in blood samples.

Development and validation of an on-line multidimensional SPE-LC-MS/MS method for the quantitation of Tetrandrine in blood samples.

Journal of chromatography. B, Analytical technologies in the biomedical and life sciences (2015-03-10)
Sena Caglar, Rosa Morello, Karl-Siegfried Boos
摘要

On-line solid-phase extraction (SPE) is becoming an increasingly widespread technique in the clean-up of complex matrices such as body fluids, prior to chromatographic analysis. The use of small SPE columns instead of disposable SPE cartridges allows multiple injections and complete automation. In addition, it decreases the cost of consumables and improves the quality of the overall analysis. Coupling of SPE with HPLC combines sample preparation and separation in one system. In this paper a validated on-line multidimensional (MD) SPE-LC-MS/MS method is described for the determination of Tetrandrine (model drug) in human blood samples. The developed method showed the applicability of direct injection of plasma samples to an on-line MD-SPE-LC-MS/MS system to determine small molecules i.e. drugs. The experimental design is unique. Quantification was through tandem mass spectrometry with positive electrospray ionization (ESI) and multiple reactions monitoring (MRM). The limit of detection was calculated as 31.98 ng/mL. The linear range of the method was between 40.0 and 800.0 ng/mL. Pharmacokinetic parameters are usually determined by analysis of drug concentrations in plasma rather than whole blood. Parameters determined using plasma data may be misleading if concentrations of drug differ between plasma and red blood cells. We successfully applied the developed method for the determination of the distribution coefficient of the model drug Tetrandrine between human red blood cells and blood plasma proteins. The determination of distribution coefficient study results demonstrated that the developed method can provide direct and accurate measurement of RBC partitioning in a model drug and could be applied for screening of other compounds for potential high RBC partition, predicting potential drug toxicity and investigating mechanisms associated with RBC partitions.

材料
货号
品牌
产品描述

Sigma-Aldrich
二甲基亚砜, Hybri-Max, sterile-filtered, BioReagent, suitable for hybridoma, ≥99.7%
Sigma-Aldrich
乙腈, suitable for HPLC, gradient grade, ≥99.9%
Sigma-Aldrich
二甲基亚砜, for molecular biology
Sigma-Aldrich
二甲基亚砜, anhydrous, ≥99.9%
Sigma-Aldrich
乙腈, anhydrous, 99.8%
Sigma-Aldrich
二甲基亚砜, ACS reagent, ≥99.9%
Sigma-Aldrich
氢氧化铵 溶液, ACS reagent, 28.0-30.0% NH3 basis
Sigma-Aldrich
二甲基亚砜, sterile-filtered, BioPerformance Certified, meets EP, USP testing specifications, suitable for hybridoma
Sigma-Aldrich
二甲基亚砜, suitable for HPLC, ≥99.7%
Supelco
乙酸铵, LiChropur, eluent additive for LC-MS
Sigma-Aldrich
二甲基亚砜, ≥99.5% (GC), suitable for plant cell culture
Sigma-Aldrich
二甲基亚砜, ReagentPlus®, ≥99.5%
Sigma-Aldrich
乙腈, ACS reagent, ≥99.5%
Sigma-Aldrich
氢氧化铵 溶液, 28% NH3 in H2O, ≥99.99% trace metals basis
Sigma-Aldrich
乙腈, for HPLC, for UV, ≥99.9% (GC)
Sigma-Aldrich
乙腈, suitable for HPLC, gradient grade, ≥99.9%
Sigma-Aldrich
二甲基亚砜, puriss. p.a., ACS reagent, ≥99.9% (GC)
Sigma-Aldrich
乙酸铵, reagent grade, ≥98%
Sigma-Aldrich
乙酸铵, ACS reagent, ≥97%
Sigma-Aldrich
二甲基亚砜, meets EP testing specifications, meets USP testing specifications
Sigma-Aldrich
二甲基亚砜, BioUltra, for molecular biology, ≥99.5% (GC)
Sigma-Aldrich
乙酸铵, for molecular biology, ≥98%
Sigma-Aldrich
乙酸铵, ≥99.99% trace metals basis
Sigma-Aldrich
氢氧化铵 溶液, puriss., 30-33% NH3 in H2O
Sigma-Aldrich
乙酸铵 溶液, for molecular biology, 7.5 M
Sigma-Aldrich
氢氧化铵 溶液, puriss. p.a., reag. ISO, reag. Ph. Eur., ~25% NH3 basis
Sigma-Aldrich
氢氧化铵 溶液, BioUltra, ~1 M NH3 in H2O (T)
Sigma-Aldrich
乙酸铵 溶液, BioUltra, for molecular biology, ~5 M in H2O
Supelco
乙腈, Pharmaceutical Secondary Standard; Certified Reference Material
Sigma-Aldrich
乙酸铵, 99.999% trace metals basis