跳转至内容
Merck
CN
  • HDL size is more accurate than HDL cholesterol to predict carotid subclinical atherosclerosis in individuals classified as low cardiovascular risk.

HDL size is more accurate than HDL cholesterol to predict carotid subclinical atherosclerosis in individuals classified as low cardiovascular risk.

PloS one (2014-12-04)
Eliane Soler Parra, Natalia Baratella Panzoldo, Vanessa Helena de Souza Zago, Daniel Zanetti Scherrer, Fernanda Alexandre, Jamal Bakkarat, Valeria Sutti Nunes, Edna Regina Nakandakare, Eder Carlos Rocha Quintão, Wilson Nadruz, Eliana Cotta de Faria, Andrei C Sposito
摘要

Misclassification of patients as low cardiovascular risk (LCR) remains a major concern and challenges the efficacy of traditional risk markers. Due to its strong association with cholesterol acceptor capacity, high-density lipoprotein (HDL) size has been appointed as a potential risk marker. Hence, we investigate whether HDL size improves the predictive value of HDL-cholesterol in the identification of carotid atherosclerotic burden in individuals stratified to be at LCR. 284 individuals (40-75 years) classified as LCR by the current US guidelines were selected in a three-step procedure from primary care centers of the cities of Campinas and Americana, SP, Brazil. Apolipoprotein B-containing lipoproteins were precipitated by polyethylene glycol and HDL size was measured by dynamic light scattering (DLS) technique. Participants were classified in tertiles of HDL size (<7.57; 7.57-8.22; >8.22 nm). Carotid intima-media thickness (cIMT) <0.90 mm (80th percentile) was determined by high resolution ultrasonography and multivariate ordinal regression models were used to assess the association between cIMT across HDL size and levels of lipid parameters. HDL-cholesterol was not associated with cIMT. In contrast, HDL size >8.22 nm was independently associated with low cIMT in either unadjusted and adjusted models for age, gender and Homeostasis Model Assessment 2 index for insulin sensitivity, ethnicity and body mass index (Odds ratio 0.23; 95% confidence interval 0.07-0.74, p = 0.013). The mean HDL size estimated with DLS constitutes a better predictor for subclinical carotid atherosclerosis than the conventional measurements of plasma HDL-cholesterol in individuals classified as LCR.

材料
产品编号
品牌
产品描述

Sigma-Aldrich
甘氨酸, ReagentPlus®, ≥99% (HPLC)
Sigma-Aldrich
甘氨酸, suitable for electrophoresis, ≥99%
Sigma-Aldrich
胆固醇, Sigma Grade, ≥99%
Sigma-Aldrich
甘氨酸, BioUltra, Molecular Biology, ≥99.0% (NT)
Sigma-Aldrich
甘氨酸, from non-animal source, meets EP, JP, USP testing specifications, suitable for cell culture, ≥98.5%
Sigma-Aldrich
胆固醇, powder, BioReagent, suitable for cell culture, ≥99%
Sigma-Aldrich
SyntheChol ® NS0 补充, 500 ×, synthetic cholesterol, animal component-free, sterile-filtered, aqueous solution, suitable for cell culture
Sigma-Aldrich
胆固醇, from sheep wool, ≥92.5% (GC), powder
SAFC
甘氨酸
Supelco
胆固醇, Pharmaceutical Secondary Standard; Certified Reference Material
Supelco
甘氨酸, Pharmaceutical Secondary Standard; Certified Reference Material
Sigma-Aldrich
甘氨酸, BioXtra, ≥99% (titration)
Sigma-Aldrich
甘氨酸, ACS reagent, ≥98.5%
Supelco
胆固醇 溶液, certified reference material, 10 mg/mL in chloroform
Sigma-Aldrich
甘氨酸, 99%, FCC
Sigma-Aldrich
乙基对硫磷, ≥90%, oil
USP
甘氨酸, United States Pharmacopeia (USP) Reference Standard
Sigma-Aldrich
甘氨酸, meets analytical specification of Ph. Eur., BP, USP, 99-101% (based on anhydrous substance)
Sigma-Aldrich
甘氨酸, puriss. p.a., reag. Ph. Eur., buffer substance, 99.7-101% (calc. to the dried substance)
Supelco
乙基对氧磷, PESTANAL®, analytical standard
Supelco
甘氨酸, analytical standard, for nitrogen determination according to Kjeldahl method
甘氨酸, European Pharmacopoeia (EP) Reference Standard
SAFC
胆固醇, from sheep wool, Controlled origin, meets USP/NF testing specifications
Sigma-Aldrich
胆固醇, tested according to Ph. Eur.
Supelco
甘氨酸, certified reference material, TraceCERT®, Manufactured by: Sigma-Aldrich Production GmbH, Switzerland
Sigma-Aldrich
甘氨酸, tested according to Ph. Eur.
Sigma-Aldrich
甘氨酸, Vetec, reagent grade, 98%