跳转至内容
Merck
CN
  • Determination of N-nitrosodiethanolamine, NDELA in cosmetic ingredients and products by mixed mode solid phase extraction and UPLC-tandem mass spectrometry with porous graphitic carbon column through systemic sample pre-cleanup procedure.

Determination of N-nitrosodiethanolamine, NDELA in cosmetic ingredients and products by mixed mode solid phase extraction and UPLC-tandem mass spectrometry with porous graphitic carbon column through systemic sample pre-cleanup procedure.

Talanta (2015-03-17)
Kyung-Mi Joo, Mi-Sook Shin, Ji-hee Jung, Boo-Min Kim, John-Whan Lee, Hye-Jin Jeong, Kyung-Min Lim
摘要

A rapid, sensitive, accurate and specific ultra-performance liquid chromatography coupled to tandem mass spectrometry (UPLC-MS/MS) method for the detection of N-nitrosodiethanolamine (NDELA), a highly toxic contaminant in cosmetic raw materials and products was developed and validated. Systematized sample preparation steps were developed according to product types. Various SPE cartridges and columns were examined to establish the condition of SPE and chromatographic separation for NDELA. Sample cleanup steps consisting of solvent and liquid-liquid extraction tailored to the various sample matrix types were established prior to mixed mode SPE (Bond Elut AccuCAT). Chromatographic separation was achieved within 7 min on a porous graphitic carbon (PGC) column using a gradient elution with the mobile phase of 1mM ammonium acetate containing 0.1% acetic acid and methanol. NDELA was monitored using an electrospray positive ionization mass spectrometry in the multiple reaction monitoring (MRM) mode (m/z 134.9>103.7(quantifier) and 73.7(qualifier ion)) with d8-NDELA (m/z 143.1>111.0) as internal standard. The standard curves were linear over the concentration range of 1-100 ng/mL with a correlation coefficient higher than 0.99. The limit of detection (LOD) and the limit of quantification (LOQ) was 10 and 20 μg/kg, respectively (0.5 and 1 ng/mL in standard solution). The intra- and inter-day precisions were estimated to be below 11.1% and accuracies were within the range of 90.8-115.8%. The validated method was successfully applied to the analysis of real samples including raw materials, skin care, make-up, shampoos and hair products.

材料
产品编号
品牌
产品描述

Sigma-Aldrich
乙腈, suitable for HPLC, gradient grade, ≥99.9%
Sigma-Aldrich
甲醇, suitable for HPLC, ≥99.9%
Sigma-Aldrich
乙醇,Pure 200纯度, Molecular Biology
Sigma-Aldrich
甲醇, ACS reagent, ≥99.8%
Sigma-Aldrich
纯乙醇, 200 proof, ACS reagent, ≥99.5%
Sigma-Aldrich
二氯甲烷, suitable for HPLC, ≥99.8%, contains amylene as stabilizer
Sigma-Aldrich
甲醇, suitable for HPLC, gradient grade, ≥99.9%
Sigma-Aldrich
纯乙醇, 200 proof
Sigma-Aldrich
二氯甲烷, contains 40-150 ppm amylene as stabilizer, ACS reagent, ≥99.5%
Sigma-Aldrich
氯仿, contains 100-200 ppm amylenes as stabilizer, ≥99.5%
Sigma-Aldrich
二氯甲烷, HPLC Plus, for HPLC, GC, and residue analysis, ≥99.9%, contains 50-150 ppm amylene as stabilizer
Sigma-Aldrich
甲醇, HPLC Plus, ≥99.9%
Sigma-Aldrich
纯乙醇, 200 proof, meets USP testing specifications
Sigma-Aldrich
乙腈, ACS reagent, ≥99.5%
Sigma-Aldrich
氯仿, contains ethanol as stabilizer, ACS reagent, ≥99.8%
Sigma-Aldrich
二氯甲烷, anhydrous, ≥99.8%, contains 40-150 ppm amylene as stabilizer
Sigma-Aldrich
乙酸铵, ACS reagent, ≥97%
Sigma-Aldrich
乙腈, anhydrous, 99.8%
Sigma-Aldrich
纯乙醇, 200 proof, anhydrous, ≥99.5%
Sigma-Aldrich
甲醇, anhydrous, 99.8%
Sigma-Aldrich
乙醇,Pure 190纯度, for molecular biology
Sigma-Aldrich
乙酸铵, ≥99.99% trace metals basis
Supelco
乙酸铵, LiChropur, eluent additive for LC-MS
Sigma-Aldrich
乙腈, suitable for HPLC, gradient grade, ≥99.9%
Sigma-Aldrich
乙腈, ≥99.9% (GC)
Sigma-Aldrich
甲醇, Laboratory Reagent, ≥99.6%
Sigma-Aldrich
甲醇, suitable for HPLC, gradient grade, suitable as ACS-grade LC reagent, ≥99.9%
Sigma-Aldrich
纯乙醇, 190 proof, ACS spectrophotometric grade, 95.0%
Sigma-Aldrich
甲醇, puriss. p.a., ACS reagent, reag. ISO, reag. Ph. Eur., ≥99.8% (GC)
Sigma-Aldrich
二氯甲烷, puriss. p.a., ACS reagent, reag. ISO, ≥99.9% (GC)