跳转至内容
Merck
CN
  • Evaluation of mobile phase characteristics on three zwitterionic columns in hydrophilic interaction liquid chromatography mode for liquid chromatography-high resolution mass spectrometry based untargeted metabolite profiling of Leishmania parasites.

Evaluation of mobile phase characteristics on three zwitterionic columns in hydrophilic interaction liquid chromatography mode for liquid chromatography-high resolution mass spectrometry based untargeted metabolite profiling of Leishmania parasites.

Journal of chromatography. A (2014-08-28)
Rong Zhang, David G Watson, Lijie Wang, Gareth D Westrop, Graham H Coombs, Tong Zhang
摘要

It has been reported that HILIC column chemistry has a great effect on the number of detected metabolites in LC-HRMS-based untargeted metabolite profiling studies. However, no systematic investigation has been carried out with regard to the optimisation of mobile phase characteristics. In this study using 223 metabolite standards, we explored the retention mechanisms on three zwitterionic columns with varied mobile phase composition, demonstrated the interference from poor chromatographic peak shapes on the output of data extraction, and assessed the quality of chromatographic signals and the separation of isomers under each LC condition. As expected, on the ZIC-cHILIC column the acidic metabolites showed improved chromatographic performance at low pH which can be attributed to the opposite arrangement of the permanently charged groups on this column in comparison with the ZIC-HILIC column. Using extracts from the protozoan parasite Leishmania, we compared the numbers of repeatedly detected LC-HRMS features under different LC conditions with putative identification of metabolites not amongst the standards being based on accurate mass (±3ppm). Besides column chemistry, the pH of the mobile phase plays a key role in not only determining the retention mechanisms of solutes but also the output of the LC-HRMS data processing. Fast evaporation of ammonium carbonate produced less ion suppression in ESI source and consequently improved the detectability of the metabolites in low abundance in comparison with other ammonium salts. Our results show that the combination of a ZIC-pHILIC column with an ammonium carbonate mobile phase, pH 9.2, at 20mM in the aqueous phase or 10mM in both aqueous and organic mobile phase components, provided the most suitable LC conditions for LC-HRMS-based untargeted metabolite profiling of Leishmania parasite extracts. The signal reliability of the mass spectrometer used in this study (Exactive Orbitrap) was also investigated.

材料
产品编号
品牌
产品描述

乙腈, suitable for HPLC, gradient grade, ≥99.9%
甲醇, suitable for HPLC, ≥99.9%
甲醇, ACS reagent, ≥99.8%
氢氧化铵 溶液, ACS reagent, 28.0-30.0% NH3 basis
甲醇, suitable for HPLC, gradient grade, ≥99.9%
氯仿, contains 100-200 ppm amylenes as stabilizer, ≥99.5%
甲醇, HPLC Plus, ≥99.9%
乙腈, ACS reagent, ≥99.5%
氯仿, contains ethanol as stabilizer, ACS reagent, ≥99.8%
乙酸铵, ACS reagent, ≥97%
乙腈, anhydrous, 99.8%
氢氧化铵 溶液, 28% NH3 in H2O, ≥99.99% trace metals basis
Supelco
甲酸铵, eluent additive for LC-MS, LiChropur, ≥99.0%
甲醇, anhydrous, 99.8%
Sigma-Aldrich
碳酸铵, ACS reagent, ≥30.0% NH3 basis
Sigma-Aldrich
甲酸铵, reagent grade, 97%
乙酸铵, ≥99.99% trace metals basis
乙酸铵, LiChropur, eluent additive for LC-MS
乙腈, suitable for HPLC, gradient grade, ≥99.9%
乙腈, ≥99.9% (GC)
甲醇, Laboratory Reagent, ≥99.6%
甲醇, suitable for HPLC, gradient grade, suitable as ACS-grade LC reagent, ≥99.9%
甲醇, puriss. p.a., ACS reagent, reag. ISO, reag. Ph. Eur., ≥99.8% (GC)
Sigma-Aldrich
甲酸铵, ≥99.995% trace metals basis
氢氧化铵 溶液, puriss., 30-33% NH3 in H2O
甲醇, ACS spectrophotometric grade, ≥99.9%
氯仿, contains amylenes as stabilizer, ACS reagent, ≥99.8%
乙酸铵, Molecular Biology, ≥98%
甲醇, ACS reagent, ≥99.8%
Sigma-Aldrich
碳酸铵, 99.999% trace metals basis