跳转至内容
Merck
CN
  • Novel molecularly imprinted stir bar sorptive extraction based on an 8-electrode array for preconcentration of trace exogenous estrogens in meat.

Novel molecularly imprinted stir bar sorptive extraction based on an 8-electrode array for preconcentration of trace exogenous estrogens in meat.

Analytica chimica acta (2014-12-04)
Li Qiao, Ning Gan, Jiayu Wang, Huiju Gao, Futao Hu, Hongfei Wang, Tianhua Li
摘要

A novel 8-electrode array as stir bar was designed for selective extraction of trace level exogenous estrogens from food samples, followed by liquid desorption and HPLC-photodiode array detection. The array consisted of 8 screen-printed electrodes and each electrode was modified with Fe3O4@meso-/macroporous TiO2 microspheres and molecularly imprinted film (m-TiMIF). The fabrication of the imprinted film coating was very simple without organic solvents and chemical grafting. Both bisphenol A (BPA) and diethylstilbestrol (DES) were employed as templates in m-TiMIF fabrication in order to enrich both targets simultaneously. Interestingly, the imprinted stir bar array showed higher extraction capacity and selectivity for BPA and DES than the non-imprinted counterpart. Meanwhile, it exhibited fast adsorption and desorption kinetics due to increased mass transport in the ultra-thin film. Importantly, the m-TiMIF coating was robust enough for at least 20 uses without obvious alteration in extraction performance. The main parameters affecting the extraction efficiency, including stir speeding, sample pH, ionic strength, extraction time, desorption solvent and time, were optimized. Under optimal experimental conditions, the limits of detection (S/N=3) of the developed method were 0.28 and 0.47 μg L(-1) for BPA and DES respectively, with enrichment factors of 32.6 and 52.8-fold. The linear ranges were 3.0-1500 μg L(-1) and 4.0-1500 μg L(-1) for BPA and DES, respectively. The m-TiMIF-coating conferred better recovery and selectivity, compared with the commercial stir bar coating. The new method was successfully applied to assess BPA and DES in pork and chicken samples with satisfactory recovery.

材料
产品编号
品牌
产品描述

Sigma-Aldrich
2-丙醇, suitable for HPLC, 99.9%
Sigma-Aldrich
2-丙醇, ACS reagent, ≥99.5%
Sigma-Aldrich
乙酸钠, anhydrous, ReagentPlus®, ≥99.0%
Sigma-Aldrich
2-丙醇, BioReagent, ≥99.5%, Molecular Biology
Sigma-Aldrich
异丙醇, meets USP testing specifications
Sigma-Aldrich
2-丙醇, HPLC Plus, for HPLC, GC, and residue analysis, 99.9%
Sigma-Aldrich
乙酸钠, ACS reagent, ≥99.0%
Sigma-Aldrich
盐酸多巴胺 盐酸盐
Sigma-Aldrich
2-丙醇, anhydrous, 99.5%
Sigma-Aldrich
2-丙醇, puriss. p.a., ACS reagent, reag. ISO, reag. Ph. Eur., ≥99.8% (GC)
Sigma-Aldrich
2-丙醇, Laboratory Reagent, ≥99.5%
Sigma-Aldrich
苯酚 溶液, Equilibrated with 10 mM Tris HCl, pH 8.0, 1 mM EDTA, BioReagent, Molecular Biology
Sigma-Aldrich
乙酸钠, puriss. p.a., ACS reagent, reag. Ph. Eur., anhydrous
Sigma-Aldrich
钛酸四丁酯, reagent grade, 97%
Sigma-Aldrich
苯酚, puriss., ≥99.5% (GC), meets analytical specification of Ph. Eur., BP, USP, crystalline (detached)
Sigma-Aldrich
异丙醇, ≥99.7%, FCC, FG
Sigma-Aldrich
2-丙醇, puriss. p.a., ACS reagent, ≥99.8% (GC)
Sigma-Aldrich
乙酸钠, anhydrous, Molecular Biology, ≥99%
Sigma-Aldrich
氯化铁(III), anhydrous, powder, ≥99.99% trace metals basis
Sigma-Aldrich
2-丙醇, BioUltra, Molecular Biology, ≥99.5% (GC)
Sigma-Aldrich
苯酚 溶液, Saturated with 0.01 M citrate buffer, pH 4.3 ± 0.2, BioReagent, Molecular Biology
Sigma-Aldrich
苯酚, ≥99%
Supelco
2-丙醇, Pharmaceutical Secondary Standard; Certified Reference Material
Sigma-Aldrich
液状苯酚, ≥89.0%
Sigma-Aldrich
苯酚, puriss. p.a., ACS reagent, reag. Ph. Eur., 99.0-100.5%
Sigma-Aldrich
乙酸钠, 99.995% trace metals basis
Supelco
苯酚, Pharmaceutical Secondary Standard; Certified Reference Material
Sigma-Aldrich
乙酸钠, >99%, FG
Sigma-Aldrich
三氯化铁 溶液, purum, 45% FeCl3 basis
USP
苯酚, United States Pharmacopeia (USP) Reference Standard