跳转至内容
Merck
CN
  • Ionic liquid intercalated clay sorbents for micro solid phase extraction of steroid hormones from water samples with analysis by liquid chromatography-tandem mass spectrometry.

Ionic liquid intercalated clay sorbents for micro solid phase extraction of steroid hormones from water samples with analysis by liquid chromatography-tandem mass spectrometry.

Journal of chromatography. A (2014-08-19)
Can Aftafa, Füsun Okçu Pelit, Esra Evrim Yalçinkaya, Hayati Turkmen, Ilgi Kapdan, F Nil Ertaş
摘要

Clay material plays an important role in the transport and retention of many compounds in the soil, therefore, clay based sorbents are promising alternatives for selective sorption of organic pollutants. In the present work, different chain length ionic liquids (ILs) namely, 1-methyl-3-octyl-imidazolium bromide, 1-methyl-3-undecyl-imidazolium bromide and 1-methyl-3-octadecyl-imidazolium bromide were intercalated in the galleries of montmorillonite (MMT) clay. Then, this novel nanofiller surface was utilized in micro extraction of estrogenic hormones for the first time. A fast procedure where sonication-assisted emulsification microextraction combined with vortex assisted micro-solid phase extraction (μ-SPE) was developed for the LC-MS/MS analysis of estrone (E1), 17β-estradiol (E2), estriol (E3) and ethynylestradiol (EE2). The parameters related to the μ-SPE procedure namely; pH, sorbent amount, extraction solvent type and volume, sonication and vortex time, sample volume and salt effect on the extraction efficiency were screened by applying Plackett-Burmann design. The selected parameters were then optimized by using Box-Behnken design. The method was validated for the determination of estrogenic hormone residues in river water samples. Linear calibration plots were obtained for all hormones whose regression coefficients were larger than 0.98. RSD values were found less than 10% for three levels of concentration. LOD levels were calculated as; 0.012, 0.062, 0.018 and 0.693 ng L(-1) for E1, E2, E3 and EE2, respectively. Recovery values were calculated in the range of 86.9-97.7%. Considering large sample volumes required for attaining low limits of these hormones, present method provides an ease for analyst as 10 mL of the sample is adequate for achieving the same sensitivity.

材料
产品编号
品牌
产品描述

Sigma-Aldrich
乙腈, suitable for HPLC, gradient grade, ≥99.9%
Sigma-Aldrich
乙酸乙酯, ACS reagent, ≥99.5%
Sigma-Aldrich
乙酸, glacial, ACS reagent, ≥99.7%
Sigma-Aldrich
乙酸乙酯, suitable for HPLC, ≥99.7%
Sigma-Aldrich
氢氧化钠, ACS reagent, ≥97.0%, pellets
Sigma-Aldrich
乙酸, glacial, ReagentPlus®, ≥99%
Sigma-Aldrich
甲苯, ACS reagent, ≥99.5%
Sigma-Aldrich
氢氧化钠, reagent grade, ≥98%, pellets (anhydrous)
Sigma-Aldrich
氢氧化钠 溶液, 50% in H2O
Sigma-Aldrich
正己烷, suitable for HPLC, ≥97.0% (GC)
Sigma-Aldrich
甲苯, suitable for HPLC, 99.9%
Sigma-Aldrich
乙酸乙酯, HPLC Plus, for HPLC, GC, and residue analysis, 99.9%
Sigma-Aldrich
乙腈, ACS reagent, ≥99.5%
Sigma-Aldrich
正己烷, ReagentPlus®, ≥99%
Sigma-Aldrich
甲苯, HPLC Plus, for HPLC, GC, and residue analysis, ≥99.9%
Sigma-Aldrich
正己烷, suitable for HPLC, ≥95%
Sigma-Aldrich
乙腈, anhydrous, 99.8%
Sigma-Aldrich
甲苯, anhydrous, 99.8%
Sigma-Aldrich
环己烷, ACS reagent, ≥99%
Sigma-Aldrich
氢氧化钠 溶液, BioUltra, Molecular Biology, 10 M in H2O
Sigma-Aldrich
环己烷, suitable for HPLC, ≥99.9%
Sigma-Aldrich
正己烷, puriss. p.a., ACS reagent, reag. Ph. Eur., ≥99% (GC)
Sigma-Aldrich
氢氧化钠 溶液, 1.0 N, BioReagent, suitable for cell culture
Sigma-Aldrich
乙腈, suitable for HPLC, gradient grade, ≥99.9%
Sigma-Aldrich
乙酸, glacial, ≥99.99% trace metals basis
Sigma-Aldrich
正己烷, HPLC Plus, for HPLC, GC, and residue analysis, ≥95%
Sigma-Aldrich
乙腈, ≥99.9% (GC)
Sigma-Aldrich
氢氧化钠, BioXtra, ≥98% (acidimetric), pellets (anhydrous)
Sigma-Aldrich
乙酸 溶液, suitable for HPLC
Sigma-Aldrich
乙酸, glacial, puriss. p.a., ACS reagent, reag. ISO, reag. Ph. Eur., ≥99.8%