跳转至内容
Merck
CN
  • Validation of an LC-MS/MS method for the determination of zopiclone, N-desmethylzopiclone and 2-amino-5-chloropyridine in whole blood and its application to estimate the original zopiclone concentration in stored specimens.

Validation of an LC-MS/MS method for the determination of zopiclone, N-desmethylzopiclone and 2-amino-5-chloropyridine in whole blood and its application to estimate the original zopiclone concentration in stored specimens.

International journal of legal medicine (2014-07-30)
Gunnel H Nilsson, Fredrik C Kugelberg, Johan Ahlner, Robert Kronstrand
摘要

2-Amino-5-chloropyridine (ACP) is a degradation product of zopiclone (ZOP) and its two main metabolites N-desmethylzopiclone (NDZOP) and zopiclone N-oxide (ZOPNO). ACP may be formed when specimens are stored. ZOP instability in blood makes interpretation of concentrations difficult especially in cases of prolonged sample storage. This study investigated how ACP could be used to estimate the original concentration of ZOP in authentic samples. For that purpose, an analytical liquid chromatography tandem mass spectrometry (LC-MS/MS) method for the quantitation of ACP, ZOP, and NDZOP in blood was developed and validated. Due to poor extraction recovery, ZOPNO was not included in the analytical method. The method was then applied to investigate ACP formation, ZOP and NDZOP degradation in stored ZOP post-dosed authentic whole blood and two mathematical models were used to calculate the original concentration of ZOP. During storage, ACP was formed in amounts equimolar to the ZOP and NDZOP degradation. Results from samples in which ACP had been formed were used to test two models to estimate the original ZOP concentration. The correlation tests of the models showed strong correlations to the original ZOP concentration (r = 0.960 and r = 0.955) with p < 0.01 and explained more than 90 % of the ZOP concentration. This study showed that the equimolar degradation of ZOP and NDZOP to ACP could be used to estimate the original concentration of ZOP.

材料
产品编号
品牌
产品描述

Sigma-Aldrich
乙腈, suitable for HPLC, gradient grade, ≥99.9%
Sigma-Aldrich
甲醇, suitable for HPLC, ≥99.9%
Sigma-Aldrich
甲醇, ACS reagent, ≥99.8%
Sigma-Aldrich
盐酸, ACS reagent, 37%
Sigma-Aldrich
乙酸, glacial, ACS reagent, ≥99.7%
Sigma-Aldrich
甲醇, suitable for HPLC, gradient grade, ≥99.9%
Sigma-Aldrich
Trizma ® 碱, Primary Standard and Buffer, ≥99.9% (titration), crystalline
Sigma-Aldrich
乙酸, glacial, ReagentPlus®, ≥99%
Sigma-Aldrich
甲醇, HPLC Plus, ≥99.9%
Sigma-Aldrich
盐酸, ACS reagent, 37%
Sigma-Aldrich
丁基甲基醚, suitable for HPLC, ≥99.8%
Sigma-Aldrich
乙腈, ACS reagent, ≥99.5%
Sigma-Aldrich
乙酸铵, ACS reagent, ≥97%
Sigma-Aldrich
乙腈, anhydrous, 99.8%
Sigma-Aldrich
Trizma ® 碱, BioPerformance Certified, meets EP, USP testing specifications, suitable for cell culture, ≥99.9% (titration)
Sigma-Aldrich
丁基甲基醚, ACS reagent, ≥99.0%
Sigma-Aldrich
甲醇, anhydrous, 99.8%
Sigma-Aldrich
丁基甲基醚, HPLC Plus, for HPLC, GC, and residue analysis, 99.9%
Sigma-Aldrich
乙酸铵, ≥99.99% trace metals basis
Supelco
乙酸铵, LiChropur, eluent additive for LC-MS
Sigma-Aldrich
盐酸 溶液, 1.0 N, BioReagent, suitable for cell culture
Sigma-Aldrich
乙腈, suitable for HPLC, gradient grade, ≥99.9%
Sigma-Aldrich
乙酸, glacial, ≥99.99% trace metals basis
Sigma-Aldrich
乙腈, ≥99.9% (GC)
Sigma-Aldrich
乙酸 溶液, suitable for HPLC
Sigma-Aldrich
乙酸, glacial, puriss. p.a., ACS reagent, reag. ISO, reag. Ph. Eur., ≥99.8%
Sigma-Aldrich
乙酸, glacial, puriss., meets analytical specification of Ph. Eur., BP, USP, 99.8-100.5%
Sigma-Aldrich
甲醇, Laboratory Reagent, ≥99.6%
Sigma-Aldrich
甲醇, suitable for HPLC, gradient grade, suitable as ACS-grade LC reagent, ≥99.9%
Sigma-Aldrich
盐酸, meets analytical specification of Ph. Eur., BP, NF, fuming, 36.5-38%