Merck
CN
  • Anti-epidermal growth factor receptor conjugated mesoporous zinc oxide nanofibers for breast cancer diagnostics.

Anti-epidermal growth factor receptor conjugated mesoporous zinc oxide nanofibers for breast cancer diagnostics.

Nanoscale (2015-03-27)
Md Azahar Ali, Kunal Mondal, Chandan Singh, Bansi Dhar Malhotra, Ashutosh Sharma
摘要

We report the fabrication of an efficient, label-free, selective and highly reproducible immunosensor with unprecedented sensitivity (femto-molar) to detect a breast cancer biomarker for early diagnostics. Mesoporous zinc oxide nanofibers (ZnOnFs) are synthesized by electrospinning technique with a fiber diameter in the range of 50-150 nm. Fragments of ZnOnFs are electrophoretically deposited on an indium tin oxide glass substrate and conjugated via covalent or electrostatic interactions with a biomarker (anti-ErbB2; epidermal growth factor receptor 2). Oxygen plasma treatment of the carbon doped ZnOnFs generates functional groups (-COOH, -OH, etc.) that are effective for the conjugation of anti-ErbB2. ZnOnFs without plasma treatment that conjugate via electrostatic interactions were also tested for comparison. Label-free detection of the breast cancer biomarker by this point-of-care device is achieved by an electrochemical impedance technique that has high sensitivity (7.76 kΩ μM(-1)) and can detect 1 fM (4.34 × 10(-5) ng mL(-1)) concentration. The excellent impedimetric response of this immunosensor provides a fast detection (128 s) in a wide detection test range (1.0 fM-0.5 μM). The oxy-plasma treated ZnOnF immunoelectrode shows a higher association constant (404.8 kM(-1) s(-1)) indicating a higher affinity towards the ErbB2 antigen compared to the untreated ZnOnF immunoelectrode (165.6 kM(-1) s(-1)). This sensor is about an order of magnitude more sensitive than the best demonstrated in the literature based on different nanomaterials and about three orders of magnitude better than the ELISA standard for breast cancer biomarker detection. This proposed point-of-care cancer diagnostic offers several advantages, such as higher stability, rapid monitoring, simplicity, cost-effectiveness, etc., and should prove to be useful for the detection of other bio- and cancer markers.

材料
货号
品牌
产品描述

Sigma-Aldrich
甘油, for molecular biology, ≥99.0%
Sigma-Aldrich
甘油, ACS reagent, ≥99.5%
Sigma-Aldrich
甘油, ≥99.5%
Sigma-Aldrich
甘油, ReagentPlus®, ≥99.0% (GC)
Sigma-Aldrich
1,2-二氯乙烷, anhydrous, 99.8%
Sigma-Aldrich
N-羟基丁二酰亚胺, 98%
Sigma-Aldrich
1,2-二氯乙烷, ACS reagent, ≥99.0%
Supelco
甘油, Pharmaceutical Secondary Standard; Certified Reference Material
Sigma-Aldrich
甘油, BioXtra, ≥99% (GC)
Sigma-Aldrich
甘油, BioReagent, suitable for cell culture, suitable for insect cell culture, suitable for electrophoresis, ≥99% (GC)
Sigma-Aldrich
甘油 溶液, 83.5-89.5% (T)
Sigma-Aldrich
萘, 99%
Sigma-Aldrich
甘油, meets USP testing specifications
USP
甘油, United States Pharmacopeia (USP) Reference Standard
Sigma-Aldrich
甘油, FCC, FG
Sigma-Aldrich
甘油, BioUltra, for molecular biology, anhydrous, ≥99.5% (GC)
Sigma-Aldrich
甘油, puriss., anhydrous, 99.0-101.0% (alkalimetric)
Sigma-Aldrich
蒽, ReagentPlus®, 99%
Supelco
萘, analytical standard
Sigma-Aldrich
甘油 溶液, puriss., meets analytical specification of Ph. Eur., BP, 84-88%
Supelco
甘油, analytical standard
Sigma-Aldrich
甘油, puriss. p.a., ACS reagent, anhydrous, dist., ≥99.5% (GC)
Sigma-Aldrich
蒽, reagent grade, 97%
Supelco
熔点标准品 79-81°C, analytical standard
Sigma-Aldrich
甘油, tested according to Ph. Eur., anhydrous
Sigma-Aldrich
N-羟基丁二酰亚胺, purum, ≥97.0% (T)
Supelco
1,2-二氯乙烷, analytical standard
Supelco
萘, Pharmaceutical Secondary Standard; Certified Reference Material
Supelco
蒽, analytical standard
Sigma-Aldrich
萘, suitable for scintillation, ≥99%